Menu
Siemens patches critical SCADA flaws likely exploited in recent attacks

Siemens patches critical SCADA flaws likely exploited in recent attacks

The vulnerabilities allow remote attackers to extract files from WinCC SCADA servers and execute arbitrary code on them

Siemens released security updates for several of its SCADA (supervisory control and data acquisition) products for industrial environments, in order to fix critical vulnerabilities that may have been exploited in recent attacks.

One of the vulnerabilities allows unauthenticated attackers to remotely execute arbitrary code on a Siemens SIMATIC WinCC SCADA server by sending specially crafted packets to it. The flaw received the maximum severity score of 10 in the Common Vulnerability Scoring System and can lead to a full system compromise.

The other vulnerability can also be exploited by unauthenticated attackers by sending specially crafted packets, but to extract arbitrary files from the WinCC server. The flaw has a CVSS score of 7.8.

According to the Industrial Control Systems Cyber Emergency Response Team (ICS-CERT), a division of the U.S. Department of Homeland Security, it's likely that attackers are already aware of these vulnerabilities and are exploiting them.

"Exploits that target these vulnerabilities are potentially available," ICS-CERT said in a security advisory Tuesday. "Indicators exist that this vulnerability may have been exploited during a recent campaign."

ICS-CERT did not say to which campaign it was referring, but last month the organization issued an alert about attacks that installed a backdoor program called BlackEnergy on industrial control systems. ICS-CERT had reasons to believe at the time that the campaign also targeted Siemens' SIMATIC WinCC among products from other vendors, although the attack vector for WinCC was unknown.

According to an advisory published by Siemens last week, the newly patched flaws affect SIMATIC WinCC 7.3, 7.2, 7.0 SP3, 7.0 SP2 and earlier versions. Versions 8.1, 8.0, 7.1 SP4 and earlier of the SIMATIC PCS 7 distributed control system and version 13 of the TIA Portal engineering software are also affected because they include WinCC.

The company released WinCC 7.2 Update 9 and WinCC 7.3 Update 2 to address the flaws. SIMATIC PCS users are advised to upgrade to version 8.0 SP2 with WinCC V7.2 Update 9 or version 8.1 with WinCC V7.3 Update 2. TIA Portal users should upgrade to version 13 Update 6.

Siemens is also working on updates for individual PCS components that will be released in the future, namely OpenPCS 7 V8.0.1 Update 5 and V8.1 Update 1; Route Control V8.0.1 Update 4 and V8.1 Update 1 and BATCH V8.0.1 Update 11 and V8.1.1 Update 1.

The company advised administrators to run WinCC servers and engineering stations only within trusted networks, to ensure they communicate only through encrypted channels -- by using VPN tunnels or by activating the Encrypted Communications feature in WinCC -- and to restrict access to WinCC servers to trusted entities only. Customers should also use up-to-date application whitelisting software and virus scanners, the company said.

The number of attacks against SCADA users has grown this year. Since June, security researchers have identified two malware campaigns targeting such systems: Havex and BlackEnergy.


Follow Us

Join the newsletter!

Or

Sign up to gain exclusive access to email subscriptions, event invitations, competitions, giveaways, and much more.

Membership is free, and your security and privacy remain protected. View our privacy policy before signing up.

Error: Please check your email address.

Tags malwareintrusionsiemenspatchesExploits / vulnerabilitiesIndustrial Control Systems Cyber Emergency Response Team

Featured

Slideshows

The making of an MSSP: a blueprint for growth in NZ

The making of an MSSP: a blueprint for growth in NZ

Partners are actively building out security practices and services to match, yet remain challenged by a lack of guidance in the market. This exclusive Reseller News Roundtable - in association with Sophos - assessed the making of an MSSP, outlining the blueprint for growth and how partners can differentiate in New Zealand.

The making of an MSSP: a blueprint for growth in NZ
Reseller News Platinum Club celebrates leading partners in 2018

Reseller News Platinum Club celebrates leading partners in 2018

The leading players of the New Zealand channel came together to celebrate a year of achievement at the inaugural Reseller News Platinum Club lunch in Auckland. Following the Reseller News Innovation Awards, Platinum Club provides a platform to showcase the top performing partners and start-ups of the past 12 months, with more than ​​50 organisations in the spotlight.​​​

Reseller News Platinum Club celebrates leading partners in 2018
Meet the top performing HP partners in NZ

Meet the top performing HP partners in NZ

HP has honoured its leading partners in New Zealand during 2018, following 12 months of growth through the local channel. Unveiled during the fourth running of the ceremony in Auckland, the awards recognise and celebrate excellence, growth, consistency and engagement of standout Kiwi partners.

Meet the top performing HP partners in NZ
Show Comments